LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2010 >> Lancer Evolution SE >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 99 (Door System - Lancer Evolution) >> Symptom Procedures <Power Window> >> INSPECTION PROCEDURE 5: The Power Window Timer Function does not work Normally >> Diagnostic Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Procedure

WARNING: This page is about a different variant/trim than selected.

Required Special Tools: 

  1. STEP 1. Check the power supply system. 

    With the ignition switch in the LOCK (OFF) position, check if the following function operates normally:

  2. STEP 2. Using scan tool MB991958, check data list. 

    Check the signals related to the power window timer function operation.

    CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991958.
    1. Connect scan tool MB991958. Refer to "HOW TO CONNECT SCAN TOOL (M.U.T.-III) ."
    2. Turn the ignition switch to the "ON" position.
    3. Check the data list of the ETACS.
      • Turn the ignition switch to the LOCK (OFF) position.
      • Close the driver's door.
      • Close the passenger's door.
        ITEM CHART

        Item No. Item name Normal condition
        254 IG voltage Battery positive voltage
        256 Dr door ajar switch Close
        257 As door ajar switch Close
    4. Turn the ignition switch to the "LOCK" (OFF) position.
      Fig 1: Connecting Special Tool MB991910 To Data Link Connector
      G05373979Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

      OK: Normal condition is displayed. 

      Q: Is the check result normal? 

  3. STEP 3. Retest the system. 

    Check that the power window timer function works normally.

    Q: Is the check result normal? 

    • YES:  No action is necessary and testing is complete.
    • NO:  Replace the power window main switch. Check that the power window timer function works normally.