>> A << Band Installation
CAUTION:
- Hold the rack housing, and use special tool bellows band clipping tool (MB992209) to crimp the bellows band securely.
- Crimp the special tool bellows band clipping tool (MB992209) touches the stopper.
- Use special tool bellows band clipping tool (MB992209) to crimp the bellows band.
- Check that crimped width (A) is within the standard value.
Standard value (A): 2.4 - 2.8 mm (0.09 - 0.11 in)