Diagnostic Procedure
- STEP 1. Check the following connector:
- C-40 TCM connector
- B-07 Primary pulley speed sensor connector
- B-113 Secondary pulley speed sensor connector
Check for the connection with terminals.
Q: Is the check result normal?
- YES: Go to Step 2.
- NO: Repair the defective connector.
- STEP 2. Use an oscilloscope to measure the wave patterns of the primary pulley speed sensor and secondary pulley speed sensor.
Refer to OSCILLOSCOPE INSPECTION PROCEDURES .
Q: Is the check result normal?
- YES: Go to Step 3.
- NO: Replace the primary pulley speed sensor or secondary pulley speed sensor.
- STEP 3. Symptom recheck after erasing diagnosis code
Q: Is the check result normal?
- YES: Intermittent malfunction
- NO: Replace TCM.