Service Specifications
SERVICE SPECIFICATIONS
| Item | Standard value | |
|---|---|---|
| Transmission fluid temperature sensor resistance kΩ | at 0°C (32°F) | Approximately 15.5 |
| at 20°C (68°F) | Approximately 6.5 | |
| at 40°C (104°F) | Approximately 3.1 | |
| at 60°C (140°F) | Approximately 1.6 | |
| at 80°C (176°F) | Approximately 0.9 | |
| at 100°C (212°F) | Approximately 0.5 | |
| Line pressure solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω | Approximately 5.6 to 6.6 | |
| Secondary pressure solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω | Approximately 5.6 to 6.6 | |
| Lockup/select switching solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω | Approximately 25.5 to 29.3 | |
| Lockup solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω | Approximately 5.6 to 6.6 | |
| Shift lock solenoid resistance Ω | 24 ± 1.2 | |
| Engine stall speed r/min | D range | 2,400 - 2,900 |
| R range | 2,400 - 2,900 | |
| Opening temperature of thermo valve °C (°F) | 75 ± 1.5 (167 ± 2.7) | |
| Full opening temperature of thermo valve °C (°F) | 95 (203) or more | |
| Amount of thermo valve lift when it is fully opened mm (in) | 3 (0.12) or more | |