>>H<< Control Housing Installation
CAUTION:
Squeeze sealant onto the case. Do not leave gaps or excess amounts, otherwise oil leaks are likely.
- Completely degrease the FIPG-applied surface so that water and oil including the old sealant cannot adhere to the surface coated with the sealant.
Never touch the degreased surface by hand.
- Apply a 1.5 mm (0.06 inch) diameter bead of sealant (Mitsubishi Part number MD997740 or equivalent) as illustrated onto the control housing.NOTE: Be sure to install the housing to the case quickly while the sealant is still wet.
- Install the control housing to the transaxle case and tighten the bolts to specified torque.
Tightening torque: 18 ± 3 N.m (13 ± 2 ft-lb)
NOTE: After installation, keep the sealed area away from the oil for approximately one hour.