How To Operate The Scan Tool MB991958: Notes
CAUTION:
Before setting, if the combination meter does not start measuring the elapsed time, turn the ignition switch to the ON position while pressing the meter information switch to start a measurement.
- Connect the scan tool MB991958 to the data link connector.
- Start the M.U.T.-III system on the PC and turn the ignition switch to the "ON" position.
- Select "Meter" on the "System Select" screen, and press the "OK" button.
- Select "Special Function" on the next screen.
- Select "Service Reminder" on the "Special function" screen.
- Select the function to be executed from "Function List."
- 1 Reminder reset (Indicator off) (Refer to 1. REMINDER RESET (INDICATOR OFF) .
- 2 Next schedule reminder cancel (Refer to 2. NEXT SCHEDULE REMINDER CANCEL .
- 3 Extra reminder setting (Refer to 3. EXTRA REMINDER SETTING .
- 4 Extra reminder cancel (Refer to 4. EXTRA REMINDER CANCEL .
- 5 Periodic reminder schedule set (Refer to 5. PERIODIC REMINDER SCHEDULE SET .
- 6 Integrated value adjustment (Refer to 6. INTEGRATED VALUE ADJUSTMENT .
- 7 Optional INT schedule setting (Refer to 7. OPTIONAL INT SCHEDULE SETTING .