Data List
NOTE:
VP: Indicates the brake vacuum pressure system.
| Item No. | Check item | Check conditions | Normal conditions |
|---|---|---|---|
| 1 | Power switch signal | When the electric motor switch is in the ON position | ON |
| Other than above | OFF | ||
| 2 | Power switch (ST) signal | When the electric motor switch is in the START position | ON |
| Other than above | OFF | ||
| 3 | Brake SW | When the brake pedal is being depressed (Stoplight switch: ON) | ON |
| Other than above | OFF | ||
| 4 | Parking brake switch | When the parking brake lever is pulled up (Parking brake switch: ON) | ON |
| Other than above | OFF | ||
| 5 | 12 V DC/DC F/B signal |
|
ON |
| Other than above | OFF | ||
| 6 | Interlock switch | When the service plug is removed | OFF |
| When the service plug is installed | ON | ||
| 7 | Radiator fan 1 relay diagnosis (cooling fan LO relay) | When the radiator fan relay is operating at low speed | ON |
| Other than above | OFF | ||
| 8 | Radiator fan 2 relay diagnosis (cooling fan HI relay) | When the radiator fan relay is operating at high speed | ON |
| Other than above | OFF | ||
| 9 | Charging contactor (diagnosis) |
|
ON |
| Other than above | OFF | ||
| 10 | Main contactor [+] (diagnosis) |
|
ON |
| Other than above | OFF | ||
| 11 | Main contactor [-] (diagnosis) |
|
ON |
| Other than above | OFF | ||
| 12 | On board charger power supply relay (diagnosis) |
|
ON |
| Other than above | OFF | ||
| 13 | A/C power supply relay (diagnosis) |
|
ON |
| Other than above | OFF | ||
| 14 | Back light relay (diagnosis) | When the selector lever is in the position other than the R position | OFF |
| When the selector lever is in the R position | ON | ||
| 15 | Diagnosis control terminal connection | When the scan tool is not connected | OFF |
| When the scan tool is connected | ON | ||
| 16 | ASC OFF switch | When the ASC OFF switch is set to OFF | OFF |
| When the ASC OFF switch is set to ON | ON | ||
| 17 | Quick charger connection flag | When quick charging is not in progress | OFF |
| When quick charging is in progress | ON | ||
| 18 | Quick charger ready signal | When quick charging is not in progress | OFF |
| When quick charging is in progress | ON | ||
| 19 | Quick charging start signal | When quick charging is not in progress | OFF |
| When quick charging is in progress | ON | ||
| 20 | On board charging start signal | When charging by the on board charger is not in progress (When the on board transformer is not operating) | OFF |
| When charging by the on board charger is in progress (When the on board transformer is operating) | ON | ||
| 25 | Shift position sw P | When the selector lever is in the position other than the P position | OFF |
| When the selector lever is in the P position | ON | ||
| 26 | Shift position sw R | When the selector lever is in the position other than the R position | OFF |
| When the selector lever is in the R position | ON | ||
| 27 | Shift position sw N | When the selector lever is in the position other than the N position | OFF |
| When the selector lever is in the N position | ON | ||
| 28 | Shift position sw D | When the selector lever is in the position other than the D position | OFF |
| When the selector lever is in the D position | ON | ||
| 29 | Shift position sw E | When the selector lever is in the position other than the E position | OFF |
| When the selector lever is in the E position | ON | ||
| 30 | Shift position sw B | When the selector lever is in the position other than the B position | OFF |
| When the selector lever is in the B position | ON | ||
| 31 | Inhibitor sw P | When the selector lever is in the position other than the P position | OFF |
| When the selector lever is in the P position | ON | ||
| 32 | Inhibitor sw R | When the selector lever is in the position other than the R position | OFF |
| When the selector lever is in the R position | ON | ||
| 33 | Inhibitor sw N | When the selector lever is in the position other than the N position | OFF |
| When the selector lever is in the N position | ON | ||
| 34 | Inhibitor sw D | When the selector lever is in the position other than the D position | OFF |
| When the selector lever is in the D position | ON | ||
| 37 | Air bag collision signal | When the judgment of high voltage shutdown is not performed | OFF |
| When the judgment of high voltage shutdown is performed | ON | ||
| 50 | IGCT control power supply relay | Always | ON |
| 51 | Charging contactor output (diagnosis) |
|
ON |
| Other than above | OFF | ||
| 52 | Main contactor (+) |
|
ON |
| Other than above | OFF | ||
| 53 | Main contactor (-) |
|
ON |
| Other than above | OFF | ||
| 54 | Motor inverter drive signal | When the selector lever is in the R, D, E, or B position while the Ready indicator is lit | ON |
| Other than above | OFF | ||
| 55 | 12 V DC/DC CONV drive signal |
|
ON |
| Other than above | OFF | ||
| 56 | Radiator fan 1 relay (cooling fan LO relay) | When the radiator fan relay is operating at low speed or high speed | ON |
| Other than above | OFF | ||
| 57 | Radiator fan 2 relay (cooling fan HI relay) | When the radiator fan relay is operating at high speed | ON |
| Other than above | OFF | ||
| 58 | Water pump relay | When the water pump is operating | ON |
| Other than above | OFF | ||
| 59 | On board charger power supply relay |
|
ON |
| Other than above | OFF | ||
| 60 | A/C relay |
|
ON |
| Other than above | OFF | ||
| 61 | Back-light relay | When the selector lever is in the position other than the R position | OFF |
| When the selector lever is in the R position | ON | ||
| 62 | Quick charging contactor | When quick charging is not in progress | OFF |
| When quick charging is in progress | ON | ||
| 63 | Vacuum P fail-safe relay (brake electric vacuum pump main relay) | When the electric motor switch is in the ON position | ON |
| 64 | Vacuum pump relay 1 (Brake electric vacuum pump control relay 1) |
|
ON |
| 65 | Vacuum pump relay 2 (Brake electric vacuum pump control relay 2) |
|
ON |
| 66 | Quick charging approval signal | When quick charging is not in progress | OFF |
| When quick charging is in progress | ON | ||
| 75 | Accelerator sensor 1 power supply voltage | - | 4.9 V - 5.1 V |
| 76 | Accelerator sensor 2 power supply voltage | - | 4.9 V - 5.1 V |
| 78 | Accelerator sensor 1 voltage | When the accelerator pedal is released | 0.8 V - 1.2 V |
| When the pedal is depressed | Increases in response to the depression amount. | ||
| Fully open | 4.0 V - 4.8 V | ||
| 79 | Accelerator sensor 2 voltage | When the pedal is released | 0.8 V - 1.2 V |
| When the pedal is depressed | Increases in response to the depression amount. | ||
| Fully open | 4.0 V - 4.8 V | ||
| 81 | Vacuum pump vacuum pressure sensor voltage (brake electric vacuum pump vacuum pressure sensor power supply voltage) | - | 4.74 V - 5.00 V |
| 82 | Coolant temperature sensor voltage | When the coolant temperature is 100°C (212°F) | 0.5 V or less |
| When the coolant temperature is -30°C (-22°F) | 4.2 V or more | ||
| 83 | Control power supply pressure (partial pressure of control power supply value by 8/16) | When the voltage of the auxiliary/12V starter battery is 8 V | 2.14 V or more |
| When the voltage of the auxiliary/12V starter battery is 16 V | 4.28 V or less | ||
| 84 | Vacuum pump relay 2 voltage (partial pressure of brake electric vacuum pump control relay 2 voltage by 8/16) | When the voltage of the auxiliary/12V starter battery is 8 V | 2.14 V or more |
| When the voltage of the auxiliary/12V starter battery is 16 V | 4.28 V or less | ||
| 85 | B/P stroke sensor voltage | When the pedal is released | 1. 4 V - 3.3 V |
| When the pedal is depressed | MAX 4.6 V | ||
| 86 | B/P stroke sensor power supply | - | 4.9 V - 5.1 V |
| 87 | Brake sensor stroke value | When the pedal is depressed | MAX 61 mm (2.4 inch) |
| 100 | Control power supply voltage | - | 8.0 V - 16.0 V |
| 127 | Accelerator opening angle (for control) | When the pedal is not depressed | 1.00 V or more |
| When pedal is depressed | 4.65 V or less | ||
| 128 | Vehicle speed | When the vehicle is driven at the speed of 40 km/h (24.9 mph) | Approximately 40 km/h (24.9 mph) |
| 142 | Charging contactor seizure flag | When the charging contactor is not seized | OFF |
| When the charging contactor is seized | ON | ||
| 143 | Contactor (+) seizure flag | When the main contactor (+) is not seized | OFF |
| When the main contactor (+) is seized | ON | ||
| 144 | Contactor (-) seizure flag | When the main contactor (-) is not seized | OFF |
| When the main contactor (-) is seized | ON | ||
| 190 | B/P stroke sensor installation | Not checked or improperly installed | NG |
| Properly installed | OK | ||
| 204 | Coolant temperature | When the coolant temperature is -20 °C (-4 °F) | -20 °C (-4 °F) |
| When the coolant temperature is 0 °C (32 °F) | 0 °C (32 °F) | ||
| When the coolant temperature is 20 °C (68 °F) | 20 °C (68 °F) | ||
| When the coolant temperature is 40 °C (104 °F) | 40 °C (104 °F) | ||
| When the coolant temperature is 80 °C (176 °F) | 80 °C (176 °F) | ||
| 205 | WP rotation | When stopped | 0 r/min |
| Being operated | 1, 000 to 5, 000 r/min | ||
| 206 | On board battery charging connection signal voltage | When the regular charging connection is not connected | 4.24 V - 4.65 V |
| When the regular charging connection is connected and the release button is ON | 1. 25 V - 1.91 V | ||
| When the regular charging connection is connected and the release button is OFF (while on board charging) | 2.42 V - 3.10 V | ||
| 207 | On board battery charging connection signal | When the regular charging connection is not connected | Not available |
| When the regular charging connection is connected and the release button is ON | Release ON | ||
| When the regular charging connection is connected and the release button is OFF (while on board charging) | Release OFF | ||
| 219 | Q. Charge Contactor Circuit status | When quick charging is in progress | OFF |
| Other than quick charging (Power switch = ON) | ON | ||
| 251 | VP: Fail-safe relay contact point state (brake electric vacuum pump main relay) | When the electric motor switch is set to the ON position | ON |
| 252 | VP: Control relay 1 state (brake electric vacuum pump control relay 1) | When the brake electric vacuum pump is operating with the electric motor switch set to the ON position | ON |
| Other than above | OFF | ||
| 253 | VP: Control relay 2 state (brake electric vacuum pump control relay 2) | When the brake electric vacuum pump is operating with the electric motor switch set to the ON position | ON |
| Other than above | OFF | ||
| 254 | VP: Motor drive state | When the brake electric vacuum pump is operating with the electric motor switch set to the ON position | ON |
| Other than above | OFF | ||
| 255 | VP: Buzzer drive state | When the brake warning tone alarm is operating with the electric motor switch set to the ON position | ON |
| Other than above | OFF | ||
| 256 | VP: Brake warning indicator drive state | When the brake warning indicator is operating with the electric motor switch set to the ON position | ON |
| Other than above | OFF | ||
| 259 | VP: Vehicle speed | When the vehicle is driven at the speed of 40 km/h (24.9 mph) | Approximately 40 km/h (24.9 mph) |