>>B<< Band Installation
CAUTION:
- Secure the rack housing, and firmly crimp the bellows band by the bellows band clipping tool (special tool: MB992209).
- Crimp the bellows band securely until the special tool (MB992209) contacts the stopper.
- Using the special tool (MB992209), crimp the bellows band.
- Check that the crimping width of the band (A) is within the range of the standard value.
Standard value (A): 2.4 - 2.8 mm (0.09 - 0.11 in)