DIAGNOSTIC ITEM 23: Diagnose When The Scan Tool Cannot Receive The Data Sent By Combination Meter: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- STEP 1. Check joint connector (CAN1) C-105 and combination meter connector C-04 for loose, corroded or damaged terminals, or terminals pushed back in the connector. CAUTION:
The strand end of the twisted wire should be within 10 cm (4 inches) from the connector. For details refer to SERVICE PRECAUTIONS .
Q: Are joint connector (CAN1) C-105 and combination meter connector C-04 in good condition?
- YES: Go to Step 2.
- NO: Repair the damaged parts.
- STEP 2. Check the wiring harness between joint connector (CAN1) C-105 and combination meter connector C-04. CAUTION:
Strictly observe the specified wiring harness repair procedure. For details refer to SERVICE PRECAUTIONS .
- Disconnect joint connector (CAN1) C-105 and combination meter connector C-04, and check the wiring harness.
- Check the wiring harness between joint connector (CAN1) C-105 (terminal 7) and combination meter connector C-04 (terminal 14)
- Check the wiring harness between joint connector (CAN1) C-105 (terminal 18) and combination meter connector C-04 (terminal 15)
Q: Is the wiring harness between joint connector (CAN1) C-105 and combination meter connector C-04 in good condition?
- YES: Check the power supply circuit of the combination meter. Refer to TROUBLE SYMPTOM CHART .
- NO: Repair the wiring harness between joint connector (CAN1) C-105 and combination meter connector C-04.