>> C << Transaxle Control Cable (Transaxle Side) Installation
- Move the selector lever to the "N" range.
- Move the manual control lever to Neutral position.
- Align the hole at the end of the manual control lever and the hole in the inhibitor switch body flange (section A - A).NOTE: Insert a 5mm round short tube (0.2 inch) into the aligned holes in the transmission range switch body flange and on the tip of the manual control lever to position the transmission range switch body.
- Use the adjusting nut to tighten the transmission control cable to the specified torque.
Tightening torque: 9.5 ± 3.5 N.m (84 ± 31 in-lb)
- Make sure that the transmission-side ranges that are corresponding to the transmission range operate and function without fail.