| Transmission fluid temperature sensor resistance kΩ |
at 0°C (32°F) |
Approximately 15.5 |
| at 20°C (68°F) |
Approximately 6.5 |
| at 40°C (104°F) |
Approximately 3.1 |
| at 60°C (140°F) |
Approximately 1.6 |
| at 80°C (176°F) |
Approximately 0.9 |
| at 100°C (212°F) |
Approximately 0.5 |
| Line pressure solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω |
Approximately 5.6 - 6.6 |
| Secondary pressure solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω |
Approximately 5.6 - 6.6 |
| Lockup/select switching solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω |
Approximately 25.5 - 29.3 |
| Lockup solenoid valve coil resistance [fluid temperature: 20°C (68°F)] Ω |
Approximately 5.6 - 6.6 |
| Shift lock solenoid resistance Ω |
24 ± 1.2 |
| Engine stall speed r/min |
D range |
2, 400 - 2, 900 |
| R range |
2, 400 - 2, 900 |