Initialization Procedure
- Move the selector lever to the P range and turn the ignition switch to the "LOCK" (OFF) position. Then, connect scan tool (M.U.T.-III) to the data link connector.
- Turn the ignition switch to the "ON" position, and then move the selector lever to the R range.
- Depress the accelerator pedal while depressing the brake pedal. (Engine stops.) Use the scan tool (M.U.T.-III) special function to execute "Reset (item No. 1: Control learning value)" while holding them in applied position.
- Set the selector lever to the P range.
- Turn the ignition switch to the "LOCK" (OFF) position, and then wait for ten seconds.
- Turn the ignition switch to the "ON" position. Execute the special function "CVT oil degradation level (item No. 1: Clear CVT oil degradation level)" on the scan tool (M.U.T.-III) to delete a transmission fluid deterioration level.