Select Control
When an operation of N โ D or P โ R range is performed, the optimal operating pressure is set based on the accelerator angle, engine speed, primary pulley speed, secondary pulley speed and turbine speed to reduce the shock caused by shifting.
CONTROL ELEMENTS AND INPUT/OUTPUT SIGNAL SPECIFICATION
| Item | Input/output signal | Control | ||||||
|---|---|---|---|---|---|---|---|---|
| Shift control | Line pressure control | Select control | Lock-up control | Fail-safe function* | ||||
| Input | Engine torque signal | x | x | x | x | x | ||
| Engine speed signal | x | x | x | x | x | |||
| Throttle position signal | x | x | x | x | - | |||
| Idle signal | x | x | - | x | - | |||
| Stoplight switch signal | x | x | x | x | - | |||
| Primary pressure sensor | - | x | - | - | x | |||
| Secondary pressure sensor | x | x | - | - | x | |||
| CVT fluid temperature sensor | x | x | x | x | x | |||
| Turbine speed sensor | x | x | x | x | x | |||
| Primary pulley speed sensor | x | x | x | x | x | |||
| Secondary pulley speed sensor | x | x | - | x | x | |||
| Transmission range switch | x | x | x | x | x | |||
| Shift switch assembly | x | x | - | x | - | |||
| Output | Line pressure solenoid valve | x | x | x | - | x | ||
| Primary pressure solenoid valve | x | x | - | - | x | |||
| Lock-up solenoid valve | - | - | - | x | x | |||
| Secondary pressure solenoid valve | x | x | - | - | x | |||
| Select solenoid valve | x | - | x | - | x | |||
| Selector lever position display | - | - | x | - | - | |||
|
NOTE:
|
||||||||