Solenoid Valve Check
WARNING: This page is about a different variant/trim than selected.
- While pressing A in the figure, turn B counterclockwise to unlock the CVT assembly connector, and disconnect the connector.
- Measure the resistance between the terminals of the applicable solenoid valves and ground.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
RESISTANCE VALUE SPECIFICATIONTerminal No. Applicable solenoid valve Resistance value Ω 1 Line pressure solenoid valve - Approximately 5.3 [Fluid temperature: 20°C (68°F)]
- Approximately 5.9 [Fluid temperature: 50°C (122°F)]
- Approximately 6.5 [Fluid temperature: 80°C (176°F)]
2 Primary pressure solenoid valve 6 Low brake solenoid valve 7 High clutch and reverse brake solenoid valve 8 Lockup solenoid valve - Approximately 6.1 [Fluid temperature: 20°C (68°F)]
- Approximately 6.8 [Fluid temperature: 50°C (122°F)]
- Approximately 7.5 [Fluid temperature: 80°C (176°F)]
-
CAUTION: When the resistance is outside the standard value, replace the valve body assembly (Refer to OIL PAN AND VALVE BODY ASSEMBLY ).