LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2017 >> Mirage G4 ES, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Continuously Variable Transaxle (CVT)) >> On-Vehicle Service >> Hydraulic Pressure Test >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Hydraulic Pressure Test: Notes

WARNING: This page is about a different variant/trim than selected.

Required Special Tools: 

CAUTION: This test must be performed with the transmission fluid temperature within the range of 70 to 80°C (158 to 176°F).
  1. Check the engine oil level, and add if necessary.
  2. Warm up the engine, and then perform test drive for approximately 10 minutes.
  3. Check the transmission fluid for leaks, level and contamination. Then top up or change if necessary.
  4. Operate the parking brake securely, and then chock the wheels.
  5. Connect the scan tool (M.U.T.-III), and then start the engine.
    WARNING: For safety, operators must not stand in front of and at the rear of the vehicle during this test.
    CAUTION: During this test, leave the brake pedal depressed fully.
  6. Use the scan tool (M.U.T.-III) (data list item number 20: Secondary pressure) to measure the secondary pressure (line pressure) by observing the conditions listed in the hydraulic pressure table.
  7. Stop the engine.
  8. If not within the standard value, take necessary steps according to the hydraulic pressure test diagnosis table.