Service Specifications

Item Standard value Limit
Generator output line voltage drop (at 30 A) V - Maximum 0.3
Output current - 70% of normal output current
Regulated voltage (Ambient temperature at voltage regulator) <2.4L Engine> -20°C (-4°F) 14.2 - 15.4 -
20°C (68°F) 13.9 - 14.9 -
60°C (140°F) 13.4 - 14.6 -
80°C (176°F) 13.1 - 14.5 -
Regulated voltage (Ambient temperature at voltage regulator) <3.0L Engine> -20°C (-4°F) 14.0 - 15.1 -
20°C (68°F) 13.7 - 14.6 -
60°C (140°F) 13.2 - 14.3 -
80°C (176°F) 12.9 - 14.1 -
Rotor resistance Ω 2.4L Engine 3 - 5 -
3.0L Engine 2.1 - 2.4 -
Brush protrusion length mm (in) - Minimum 2 (0.1)