Customization Function
By operating the ETACS system or MMCS of scan tool MB991958, the following functions can be programmed. The programmed information is held even when the battery is disconnected.
| Adjustment item (scan tool display) | Adjustment item | Adjusting contents (scan tool display) | Adjusting contents | ||
|---|---|---|---|---|---|
| ACC power auto cut | Time to ACC power cut-off when the ignition switch is in the ACC position | Disable | No function | ||
| 30 min | 30 minutes (initial condition) | ||||
| 60 min | 60 minutes | ||||
| Turn power source | Adjustment of turn-signal light operation condition | ACC or IG1 | Operable with ACC or ON position | ||
| IG1 | Operable with ON position (initial condition) | ||||
| Comfort flasher | With/without comfort flasher function | Disable | No function | ||
| Enable | With function (initial condition) | ||||
| Comfort flasher switch time | Switch operation time to activate the comfort flasher function | Normal | 0.4 second (initial condition) | ||
| Long | 0.8 second | ||||
| Hazard answer back | Adjustment of the number of keyless hazard warning light answer back flashes | Lock:1, Unlock:2 | LOCK: Flashes once, UNLOCK: Flashes twice (initial condition) | ||
| Lock:1, Unlock:0 | LOCK: Flashes once, UNLOCK: No flash | ||||
| Lock:0, Unlock:2 | LOCK: No flash, UNLOCK: Flash twice | ||||
| Lock:2, Unlock:1 | LOCK: Flash twice, UNLOCK: Flash once | ||||
| Lock:2, Unlock:0 | LOCK: Flash twice, UNLOCK: No flash | ||||
| Lock:0, Unlock:1 | LOCK: No flash, UNLOCK: Flash once | ||||
| Lock:0, Unlock:0 | No function | ||||
| Front wiper operation | Adjustment of the intermittent windshield wiper operation < vehicles without auto light > | Normal INT | Intermittent wiper interval is fixed to 4 seconds. | ||
| Variable INT | Intermittent wiper interval is calculated only by the wiper volume control. | ||||
| Speed Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed (initial condition). | ||||
| Adjustment of the intermittent windshield wiper operation < vehicles with auto light > | Normal INT | Intermittent wiper interval is fixed to 4 seconds. | |||
| Variable INT | Intermittent wiper interval is calculated only by the wiper volume control. | ||||
| Speed Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed. | ||||
| Rain Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and lighting control sensor (initial condition). | ||||
| Front/rear wiper washer | Disabling or enabling washer-linked front/rear wiper function | Only Washer | No function | ||
| Washer & Wiper | With function: Without delayed finishing wipe function (Initial condition) | ||||
| With after wipe | With function: With delayed finishing wipe function | ||||
| Intelligent washer | With/without intelligent washer function | Disable | No function | ||
| Enable | With function (initial condition) | ||||
| Intermittent time of rear wiper | Adjustment of rear wiper interval | 0 sec | No wiper interval | ||
| 4 sec | 4 seconds | ||||
| 8 sec | 8 seconds (initial condition) | ||||
| 16 sec | 16 seconds | ||||
| Rear wiper low speed mode | Disabling or enabling rear wiper continuous operation | Disabled | No function | ||
| Enabled | With function (initial condition) | ||||
| Rear wiper (linked reverse gear) | Adjustment of automatic rear window wiper operation with reverse gear engaged | Enable(R wip.ON) | Operates only when the rear wiper switch is ON. | ||
| Enable(R/F wip.) | Operates only when the front or rear wiper switch is ON (initial condition). | ||||
| Sensitivity for auto light | Lighting control sensor sensitivity (illumination intensity) < vehicles with auto light > | Level 1 bright | High-high ambient brightness | ||
| Level 2 bright | High ambient brightness | ||||
| Level 3 | Standard ambient brightness (initial condition) | ||||
| Level 4 dark | Low ambient brightness | ||||
| Level 5 dark | Low-low ambient brightness | ||||
| Welcome light | Disabling or enabling welcome light function | Disabled | No function | ||
| Small light | Tail light illuminates. (initial condition) | ||||
| Head light | Headlight illuminates. | ||||
| Coming home light | Disabling or enabling coming home light function | Disabled | No function | ||
| 15 sec | Headlight illuminates for 15 seconds. | ||||
| 30sec | Headlight illuminates for 30 seconds. (initial condition) | ||||
| 60 sec | Headlight illuminates for 60 seconds. | ||||
| 180 sec | Headlight illuminates for 180 seconds. | ||||
| Dome light delay timer with door | Adjustment of interior light delay shutdown time | 0 sec | 0 second (no delay shutdown time) | ||
| 7.5 sec | 7.5 seconds | ||||
| 15 sec | 15 seconds | ||||
| 30 sec | 30 seconds (initial condition) | ||||
| 60 sec | 60 seconds | ||||
| 120 sec | 120 seconds | ||||
| 180 sec | 180 seconds | ||||
| Headlight auto cut customize | Adjustment of headlight automatic shutdown function | Disable | No function | ||
| Enable (C-spec.) | With function (initial condition) | ||||
| Interior light auto cut timer | Adjustment of interior light automatic shutdown function operation time | Disable | No function | ||
| 3 min | 3 minutes | ||||
| 30 min | 30 minutes (initial condition) | ||||
| 60 min | 60 minutes | ||||
| Door unlock mode | Adjustment of power door locks with selective unlocking < Vehicles with keyless entry system > | All doors unlock | Without function: The first operation of keyless entry system or unlock operation by KOS unlocks all doors. | ||
| Dr door unlock | With function: The first operation of keyless entry system or unlock operation by KOS unlocks the driver's door only, and the second unlock operation within 2 seconds after that unlocks all doors. (initial condition) | ||||
| Auto door unlock | Adjustment of the auto door unlock function | Disabled | Without function (initial condition) < M/T, CVT > | ||
| Always (P pos) | With function: Operates when the shift lever or the selector lever is moved to the P position. < CVT > | ||||
| Always (Lock pos) | With function: Operates when the ignition switch is moved to the LOCK (OFF) position. < M/T, CVT > | ||||
| Duration of horn chirp | Horn sounding time during horn answer back | Short | 0.01 second (initial condition) | ||
| Long | 0.02 second | ||||
| Horn chirp by keyless | Horn chirp by keyless entry system < vehicles without auto light > | Not sound horn | No horn answerback function | ||
| Lock any time | The horn sounds when the lock button of keyless entry transmitter is pressed once. | ||||
| W lock any time | The horn sounds when the lock button of keyless entry transmitter is pressed twice. (initial condition) | ||||
| Horn chirp by keyless entry system < vehicles with auto light > | Not sound horn | No horn answerback function | |||
| Lock any time | The horn sounds when the lock button of keyless entry transmitter is pressed once. | ||||
| Lock/auto ON | During daytime, while the lighting switch is in the AUTO position, the horn sounds once when the lock is pressed once. | ||||
| W lock any time | The horn sounds when the lock button of keyless entry transmitter is pressed twice. (initial condition) | ||||
| Buzzer answer back | Adjusts the tone alarm answer back function. < Vehicles with KOS > | Not Sound Buzzer | No function | ||
| At keyless | Sounds when the keyless entry system is activated. | ||||
| At F.A.S.T.(1) | Sounds when KOS is activated (initial condition). | ||||
| At Both | Sounds when the keyless entry system or KOS is activated. | ||||
| Timer lock timer | Timer lock period adjustment | 30 sec | 30 seconds (initial condition) | ||
| 60 sec | 60 seconds | ||||
| 120 sec | 120 seconds | ||||
| 180 sec | 180 seconds | ||||
| Panic alarm switch | With/without panic alarm function | Disable | No function | ||
| Enable | With function (initial condition) | ||||
| Alarm | Enables/disables theft alarm | Disable | Without function | ||
| Enable | With function (initial condition) | ||||
| F.A.S.T.(1) key detect out fm window | With/without KOS key exterior detection function | Enable | No function | ||
| Disable | With function (initial condition) | ||||
| F.A.S.T.(1) feature | KOS function adjustment | Both enable | All KOS functions are enabled (initial condition). | ||
| DoorEntry enable | Only door entry function is enabled. | ||||
| ENG strt enable Only | engine starting function is enabled. | ||||
| Both disabled | All KOS functions are disabled. | ||||
| F.A.S.T.(1) unlock disable time | Adjusts the door unlock inhibition period after door lock is activated | 0sec | 0 seconds | ||
| 3sec | 3 seconds (initial condition) | ||||
| 5sec | 5 seconds | ||||
|
NOTE:
|
|||||