Generator Assembly: Inspection: Rotor

  1. Measure the resistance between the two slip rings of the rotor coil to check the continuity between them.

    Replace the rotor if the resistance is not within the standard value range.

    Standard value: 2.0 - 2.3? 

  2. Check the continuity between the slip rings and core.
    Fig 1: Measuring Resistance Between Slip Rings Of Rotor Coil
    G05375419Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. If continuity is present, replace the rotor.
    Fig 2: Checking Continuity Between Slip Rings And Core
    G05375420Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.