LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2018 >> Mirage SE >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Charging System Diagnosis >> Troubleshooting Guide
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Troubleshooting Guide

The charging system troubleshooting guide is shown in the following steps.

  1. STEP 1  .

    Q: Is the battery in good condition? (Refer to  FLUID LEVEL AND SPECIFIC GRAVITY CHECK  ). 

    YES:  Go to Step  2.

    NO:  Charge or replace the battery.

  2. STEP 2  .

    Q: Is the drive belt in good condition? (Refer to  DRIVE BELT TENSION CHECK AND ADJUSTMENT  ). 

    YES:  Go to Step  3.

    NO:  Adjust the belt tension or replace the belt.

  3. STEP 3  .

    Q: Does the generator malfunction light come on when the ignition switch is turned "ON" position? 

    YES:  Go to Step  4.

    NO:  Check the ignition switch (Refer to IGNITION SWITCH CHECK ).

    Check the generator malfunction light and its related circuits.

    Check the generator.

  4. STEP 4  .

    Q: Does the generator malfunction light go out after starting the engine? 

    YES:  Go to Step  5.

    NO:  Check the generator.

  5. STEP 5  .

    Q: Is an oscilloscope available? 

    YES:  Go to Step  6.

    NO:  Go to Step  7.

  6. STEP 6  .

    Q: Does the oscilloscope show a normal wave pattern? (Refer to WAVEFORM CHECK USING AN OSCILLOSCOPE ).

    YES:  Go to Step  7.

    NO:  Check the generator.

  7. STEP 7  .
    • Engine: 2, 500 r/min
    • Headlight: ON (high beam)
    • Voltage between generator terminal B and the positive battery terminal

      OK: 0.5 V or less

    • Voltage between the negative battery terminal and generator body

      OK: 0.5 V or less

    Q: Are the generator output line and ground line in good condition? 

    YES:  Go to Step  8.

    NO:  Check the generator output line and ground line.

  8. STEP 8  .

    Q: Is the output current normal? (Refer to OUTPUT CURRENT TEST ).

    YES:  Go to Step  9.

    NO:  Check the generator.

  9. STEP 9  .

    Q: Is the regulated voltage normal? (Refer to REGULATED VOLTAGE TEST ).

    YES:  Go to Step  10.

    NO:  Check the generator.

  10. STEP 10  .

    Q: Is the voltage drop in the generator output line normal? 

    YES:  Generator is normal. Check other systems.

    NO:  Check the output line.