How to write learned value to the camera-ECU
When the camera is replaced, write a learned value to the new camera-ECU according to the procedure below.
- Connect scan tool (M.U.T.-IIISE) to the data link connector (For how to connect scan tool (M.U.T.-IIISE), Refer to THE DIAGNOSTIC FUNCTION ).
- Select "Write learned value (Changed ECU)" and then "Learned value Read & save" in the special functions for the multi-around monitor system to save the learned value, which is stored in the current camera-ECU, to the scan tool (M.U.T.-IIISE).NOTE: If the learned value cannot be read, replace the camera-ECU and then calibrate the camera.
- Replace the camera-ECU (Refer to CAMERA ECU ).
- Select "Write learned value (Changed ECU)" and then "Saved learned value writing" in the special functions to write the learned value, which is stored in the scan tool (M.U.T.-IIISE), to the camera-ECU.
- If any problems are not found on the screen, the calibration is complete. If any problem is found, calibrate the camera.