Solenoid Valve Check
- While pressing A in the figure, turn B counterclockwise to unlock the CVT assembly connector, and disconnect the connector.
- Measure the resistance between the terminals of the applicable solenoid valves and the ground.
Standard value:
Terminal No. Applicable solenoid valve Resistance value Ω 1 Line pressure solenoid valve - 5.5 - 7.0 (fluid temperature: 20°C (68°F))
- 6.0 - 8.0 (fluid temperature: 50°C (122°F))
- 6.5 - 8.5 (fluid temperature: 80°C (176°F))
2 Primary pressure solenoid valve 3 Secondary pressure solenoid valve 4 Select solenoid valve 5 Lock-up solenoid valve - When the resistance is within the standard value, check the power supply circuits.
- When the resistance is outside the standard value, check the valve body harness (Refer to VALVE BODY HARNESS CHECK ).
- If the valve body harness is defective, replace it (Refer to OIL PAN AND VALVE BODY ASSEMBLY ).CAUTION: Each solenoid valve cannot be removed or replaced as a single unit.
- If the valve body wiring harness is normal, replace the valve body assembly (Refer to OIL PAN AND VALVE BODY ASSEMBLY ).
- If the valve body harness is defective, replace it (Refer to OIL PAN AND VALVE BODY ASSEMBLY ).