Descriptions Of Monitor Methods
All the conditions listed below remain for 5 seconds.
- The pulley ratio is 0.5 or more, 1.0 or less.
- The primary pulley speed is 300 r/min or more.
- The secondary pulley speed is 250 r/min or more.
- Target shifting speed is 0.1/sec or less.
- The primary pressure is outside the predetermined pressure range.