Customization Function
Using the ETACS system of scan tool (M.U.T.-III), the following functions can be programmed. The programmed information is held even when the battery is disconnected.
| Adjustment item (scan tool display) | Adjustment item | Adjusting content (scan tool display) | Adjusting content |
|---|---|---|---|
| Front wiper operation | Adjustment of the intermittent windshield wiper operation <vehicles without lighting control sensor> | Normal INT | Intermittent wiper interval is fixed to 4 seconds. |
| Variable INT | Intermittent wiper interval is calculated only by the wiper volume control. | ||
| Speed Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed (initial condition). | ||
| Adjustment of the intermittent windshield wiper operation <vehicles with lighting control sensor> | Normal INT | Intermittent wiper interval is fixed to 4 seconds. | |
| Variable INT | Intermittent wiper interval is calculated only by the wiper volume control. | ||
| Speed Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and vehicle speed. | ||
| Rain Sensitive | Intermittent wiper interval is calculated according to the intermittent wiper volume control and lighting control sensor (initial condition). | ||
| Front/rear wiper washer | Disabling or enabling washer-linked wiper function | Only Washer | No function |
| Washer & Wiper | With function: Without delayed finishing wipe function (Initial condition) | ||
| With after wipe | With function: With delayed finishing wipe function | ||
| Intelligent washer | With/without intelligent washer function | Disable | No function (Initial condition) |
| Enable | With function |