DTC Set Conditions
Check Conditions
- Voltage of battery: 10 volts or more.
- Transmission range switch position: D.
- Engine speed: 450 r/min or more.
- Primary pulley speed: More than 450 r/min
- Acceleration: -0.05G or more.
Judgment Criteria
- Pulley ratio (primary pulley speed/secondary pulley speed) more than 3.781 for 0.1 second [2 times (Interval 1 second)].
- Pulley ratio (primary pulley speed/secondary pulley speed) more than 2.981 for 0.2 second [2 times (Interval: 1 second)].