LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mitsubishi >> 2020 >> Outlander SP, AWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Service Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Specifications

Item Standard value Limit
Generator output line voltage drop (at 30 A) V - Maximum 0.3
Output current - 70 % of normal output current
Regulated voltage
(Ambient temperature at voltage regulator) <2.4L Engine>
-20°C (-4°F) 14.2 - 15.4 -
20°C (68°F) 13.9 - 14.9 -
60°C (140°F) 13.4 - 14.6 -
80°C (176°F) 13.1 - 14.5 -
Regulated voltage
(Ambient temperature at voltage regulator) <3.0L Engine>
-20°C (-4°F) 14.0 - 15.1 -
20°C (68°F) 13.7 - 14.6 -
60°C (140°F) 13.2 - 14.3 -
80°C (176°F) 12.9 - 14.1 -
Rotor resistance Ω 2.4L Engine 3 - 5 -
3.0L engine 2.1 - 2.4 -
Brush protrusion length mm (in) - Minimum 2 (0.1)