Customization Function
By operating the scan tool (M.U.T.-III) ETACS system, the following functions can be customized. The programmed information is held even when the battery is disconnected.
| Adjustment item (scan tool (M.U.T.-III) display) | Adjustment item | Adjusting content (scan tool (M.U.T.-III) display) | Adjusting content |
|---|---|---|---|
| Hazard answer back | Hazard light blink time of keyless entry hazard light answerback function | Lock:0, | Unlock:0 No function |
| Lock:2, Unlock:0 | LOCK: Flash twice, UNLOCK: No flash | ||
| Lock:0, Unlock:1 | LOCK: No flash, UNLOCK: Flash once | ||
| Lock:2, Unlock:1 | LOCK: Flash twice, UNLOCK: Flash once | ||
| Lock:0, Unlock:2 | LOCK: No flash, UNLOCK: Flash twice | ||
| Lock:1, Unlock:0 | LOCK: Flashes once, UNLOCK: No flash | ||
| Lock:1, Unlock:2 | LOCK: Flashes once, UNLOCK: Flashes twice | ||
| (Initial setting) | Timer lock timer Timer lock period adjustment | 180 sec | 180 seconds |
| 120 sec | 120 seconds | ||
| 60 sec | 60 seconds | ||
| 30 sec | 30 seconds (Initial setting) |