Generator Assembly: Inspection: Rotor

  1. Measure the resistance between the two slip rings of the rotor coil to check the continuity between them.

    Replace the rotor if the resistance is not within the standard value range.

    Standard value: 2.0 - 2.3 Ω 

  2. Check the continuity between the slip rings and core.
    G14212800Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. If continuity is present, replace the rotor.
 
G14212801Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.