Generator Assembly: Inspection: Stator
- Check the electrical continuity between the stator coil terminals.
- Check the electrical continuity of the points shown in illustration. Confirm that there is electrical continuity. If there is not, replace the stator.
| Terminal connector of tester |
Electrical continuity |
| 1 - 2 |
Presence of electrical continuity |
| 1 - 3 |
| 2 - 3 |
| 4 - 5 |
| 4 - 6 |
| 5 - 6 |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
|
- Check the insulation between the stator coil terminal and the core.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
|
- Check the electrical continuity of the points shown in illustration. Confirm that there is not electrical continuity. If there is, replace the stator.
| Terminal connector of tester |
Electrical continuity |
| 1 - Core |
Absence of electrical continuity |
| 2 - Core |
| 3 - Core |
| 4 - Core |
| 5 - Core |
| 6 - Core |
- Check the insulation between coil terminals of each group.
- Check the electrical continuity of the points shown in illustration. Confirm that there is not electrical continuity. If there is, replace the stator.
| Terminal connector of tester |
Electrical continuity |
| 1 - 4 |
Absence of electrical continuity |
| 1 - 5 |
| 1 - 6 |
| 2 - 4 |
| 2 - 5 |
| 2 - 6 |
| 3 - 4 |
| 3 - 5 |
| 3 - 6 |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
|