October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Service Specifications
| Item |
Standard value |
Limit |
| Regulated voltage (Ambient temperature at voltage regulator) |
-20°C (-4°F) |
14.2 - 15.4 |
- |
| 20°C (68°F) |
13.9 - 14.9 |
- |
| 60°C (140°F) |
13.4 - 14.6 |
- |
| 80°C (176°F) |
13.1 - 14.5 |
- |
| Generator output line voltage drop (at 30 A) V |
- |
Maximum 0.3 |
| Output current |
- |
70 % of normal output current |
| Field coil resistance Ω |
Approximately 2 - 5 |
- |
| Brush protrusion length mm (in) |
- |
Minimum 2 (0.08) |