EV Priority Mode Switch, Save/Charge Mode Switch Check
| Terminal number | Item | EV priority mode switch and SAVE/CHARGE mode switch operation | Normal conditions | |
|---|---|---|---|---|
| Continuity (Resistance) | Illumination/extinction | |||
| 1 - 8 | SAVE/CHARGE mode switch | Don not press the switch | No continuity | - |
| Press and hold the switch | Continuity exists (2Ω or less) | - | ||
| 2 - 9 | EV priority mode switch | Don not press the switch | No continuity | - |
| Press and hold the switch | Continuity exists (2Ω or less) | - | ||
| 7 - 14 | EV priority mode and SAVE/CHARGE mode indicator | Don not illuminate the position lamp | No continuity | - |
| Illuminate the position lamp | No continuity | Illumination | ||