October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Generator Assembly: Inspection: Stator
- Check the electrical continuity between the stator coil terminals.
- Check the electrical continuity of the points shown in the table below. Confirm that there is electrical continuity. If there is not, replace the generator assembly.
| Terminal connector of tester |
Electrical continuity |
| 1 - 2 |
Presence of electrical continuity |
| 1 - 3 |
| 2 - 3 |
| 4 - 5 |
| 4 - 6 |
| 5 - 6 |
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
|