Work Procedure (Group A)
| *1: | When the same malfunction is detected in two consecutive trips, MIL will illuminate. |
- CHECK DTC
Check DTC.
Is any DTC detected?
YES >>: Repair malfunction(s) and erase DTC. Refer to "DTC Index" of each Control module.
NO >>: GO TO 2 .
- CHECK PERMANENT DTC
With M.U.T.-III SE
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Select "PERMANENT DTC STATUS" mode with M.U.T.-III SE.
With GST
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Select Service $0A with GST.
Is any permanent DTC detected?
YES >>: GO TO 3 .
NO >>: END
- PERFORM DTC CONFIRMATION PROCEDURE
Perform "DTC CONFIRMATION PROCEDURE" for DTCs which are the same as permanent DTCs stored in ECM. Refer to DTC INDEX .
>>: GO TO 4 .
- CHECK PERMANENT DTC
With M.U.T.-III SE
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Select "PERMANENT DTC STATUS" mode with M.U.T.-III SE.
With GST
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Select Service $0A with GST.
Is any permanent DTC detected?
YES >>: GO TO 1.