Component Function Check
- CHECK COOLING FAN FUNCTION
With M.U.T.-III SE
- Turn ignition switch ON.
- On M.U.T.-III SE screen, select "ENGINE">> "Special Function">> "Actuator Test">> "FAN DUTY CONTROL".
- Make sure that cooling fan speed varies according to the percentage.
Without M.U.T.-III SE
- Perform IPDM E/R auto active test and check cooling fan motors operation.
- Make sure that cooling fan operates.
Is the inspection result normal?
YES >>
INSPECTION END
NO >>