Component Inspection (EGR Volume Control Valve)
- CHECK EGR VOLUME CONTROL VALVE-1
With M.U.T.-III SE
- Turn ignition switch ON (engine stopped).
- Perform "EGR CONTROL VALVE" in "Actuator Test" (in "Special Function") mode of "ENGINE" using M.U.T.-III SE.
- Set "EGR VALVE POSITION" to 0 deg, and check value "V1" of "EGR VALVE POSITION SEN".
Does "V1" become 0.5 ± 0.1 V ?
YES >>
GO TO 2
NO >>
Replace EGR volume control valve. Refer to REMOVAL AND INSTALLATION .
- CHECK EGR VOLUME CONTROL VALVE-2
With M.U.T.-III SE
Set "EGR VALVE POSITION" to 70 deg, and check value "V2" of "EGR VALVE POSITION SEN".
Does "V1" become 3.6 ±0.25 V?
YES >>
GO TO 3
NO >>
Replace EGR volume control valve. Refer to REMOVAL AND INSTALLATION .
- CHECK EGR VOLUME CONTROL VALVE-3
- Turn ignition switch OFF
- Remove EGR volume control valve. Refer to REMOVAL AND INSTALLATION .
- Check the resistance between EGR volume control valve terminals.
EGR volume control valve Resistance (Approx.) Terminal 6 5 1 - 100 Ω Is the inspection result normal?
YES >>
GO TO 4
NO >>
Replace EGR volume control valve. Refer to REMOVAL AND INSTALLATION .
- CHECK EGR VOLUME CONTROL VALVE VISUALLY
Check if any foreign objects interferes with EGR volume control valve.
Is the inspection result normal?
YES >>
INSPECTION END
NO >>
Replace or replace error-detected parts.