Component Inspection
- CHECK INTAKE AIR TEMPERATURE SENSOR
- Turn ignition switch OFF.
- Disconnect mass air flow sensor harness connector and reconnect it again.
- Turn ignition switch ON.
- Select "DATA MONITOR" mode with M.U.T.-III SE.
- Check that "INT/A TEMP SE" indicates as per following condition.
Monitor item Condition Value Values INT/A TEMP SE Temperature [°C (°F)] 25 (77) 20 - 30°C (68 - 86°F) 80 (176) 75 - 85°C (167 - 185°F)
Is the inspection result normal?
YES >>
INSPECTION END
NO >>
Replace mass air flow sensor (with intake air temperature sensor). Refer to EXPLODED VIEW .