Rectifier Assembly
Inspection of the (+) diode
- Check the electrical continuity of the points shown in the table below. Confirm that there is not electrical continuity.
If there is, replace the generator assembly.
| Measured terminal No. [Tester: (+) side - (-) side] | Continuity |
|---|---|
| B terminal - 1 | Continuity exists. |
| B terminal - 2 | |
| B terminal - 3 | |
| B terminal - 4 | |
| B terminal - 5 | |
| B terminal - 6 | |
| 1 - B terminal | No continuity |
| 2 - B terminal | |
| 3 - B terminal | |
| 4 - B terminal | |
| 5 - B terminal | |
| 6 - B terminal |
Inspection of the (-) diode
- Check the electrical continuity of the points shown in the table below. Confirm that there is not electrical continuity. If there is, replace the generator assembly.
Measured terminal No. [Tester: (+) side - (-) side] Continuity 1 - (-) Heat sink
2 - (-) Heat sinkContinuity exists. 3 - (-) Heat sink 4 - (-) Heat sink 5 - (-) Heat sink 6 - (-) Heat sink (-) Heat sink - 1 No continuity (-) Heat sink - 2 (-) Heat sink - 3 (-) Heat sink - 4 (-) Heat sink - 5 (-) Heat sink - 6