Fail-Safe Control By Power Window Motor
WARNING: This page is about a different car, the 2023 Mitsubishi Outlander PHEV. However, it is still accessible from the selected car via links, so may be relevant.
Power window motor switches power window operation to fail-safe control when malfunction is detected.
| Detected item | Judgment condition | Fail-safe operation | Recovery condition |
|---|---|---|---|
| Non-Initialized condition | When the motor integrated CPU detect door glass position non-initialized condition | Auto UP operation (Anti-pinch) is forbidden | Initialization completed |
| Thermal protection | When the motor integrated CPU detect temperature increases and exceeds threshold | Power window operation is forbidden | A period of time passed (Temperature returns to normal) |
| Consecutive reverse operation malfunction | When the motor integrated CPU has detected consecutively 3 times the reverse operation | Auto UP operation (Anti-pinch) is forbidden | Approximately 10 seconds passed or the motor integrated CPU detect door glass fully close position |