Initialisation Procedure
- After the power supply mode of the electric motor switch is OFF, connect the scan tool (M.U.T.-III SE) to the data link connector.
- Operate the electric motor switch without depressing the brake pedal and turn the power supply mode of electric motor switch to ON.
- Select "ENGINE" from System select Screen of the scan tool (M.U.T.-III SE).
- Select "Special Function" from ENGINE Screen.
- Select "Learned value reset" from Special Function Screen.
- Initialise the learning value by pressing the "OK" button.