Electric Assist Choke: Operation
As engine starts and current flows through electrical system and choke relay, electric heater in bimetallic housing is activated. This heats bimetallic spring which is attached to choke valve lever. This lever transfers the action of the heated spring to the choke valve. Position of choke valve depends on time elapsed since starting, warm up condition of engine, and ambient air temperature.