Glow Plug Control Unit
- To test pre-glow operation, connect test lamp to Blue wire of control unit (harness connector plugged in). Turn ignition on and measure amount of time test lamp is lighted. See Pre-Glow Test Specifications table.PRE-GLOW TEST SPECIFICATIONS
Coolant Temp. °F (°C) Time in Seconds Terminal Voltage Below 122 (50) 12 8 Below 122 (50) 6 10.5 Above 122 (50) 0 0 - Connect test lamp to Black/White wire of control unit. Measure amount of time that test lamp is lighted when ignition switch is turned from "START" to "ON". See After-Glow Test Specifications table. Test lamp will be on continuously with switch in "START" position.AFTER-GLOW TEST SPECIFICATIONS
Coolant Temperature °F (°C) Time in Seconds Below -13 (-25) 31 68 (20) 11 104 (40) 9 122 (50) 0 - Test lamp will turn off during after-glow operation when glow plug voltage reaches 7 volts. Replace glow plug control unit if defective.