Pressure Regulator Control Unit
This system is used to improve starting of a hot engine. It achieves this by cutting off the intake manifold vacuum signal to the pressure regulator. This system operates only when fuel temperature is above 172°F (78°C), during starting and the first 3 minutes of engine operation, and when the exhaust gas sensor heater is on.