Vacuum Control Valve
Apply vacuum to vacuum control valve, and ensure that distributor side of vacuum control valve opens or closes in response to the vacuum of carburetor side. Valve should be open when more than 1.97 in. Hg of vacuum is applied, and closed when less than 1.97 in. Hg of vacuum is applied.