Auxiliary Air Control (AAC) Solenoid
See appropriate AUXILIARY AIR CONTROL (AAC) diagnostic chart. Disconnect AAC Solenoid and check resistance across solenoid terminals. The resistance should be 10 ohms at 68°F (20°C).
See appropriate AUXILIARY AIR CONTROL (AAC) diagnostic chart. Disconnect AAC Solenoid and check resistance across solenoid terminals. The resistance should be 10 ohms at 68°F (20°C).