Home >> Nissan-Datsun >> 2002 >> Sentra SE-R Spec V >> Repair and Diagnosis (Single Page) >> External Pages >> Different car >> Section 405 (Engine Control System - DTC) >> DTC P0403: EGR Volume Control Valve >> Diagnostic Procedure >> 3. Check EGR Volume Control Valve Output Signal Circuit For Open And Short
April 5, 2026: LEMON Manuals is launched! Read the announcement.

3. Check EGR Volume Control Valve Output Signal Circuit For Open And Short

WARNING: This page is about a different car, the 2004 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check harness continuity between ECM terminals and EGR volume control valve terminals as follows. Refer to WIRING DIAGRAM.
    Fig 1: Check EGR Volume Control Valve Output Signal Circuit For Open And Short
    G00877321Courtesy of NISSAN MOTOR CO., U.S.A.
    1. Continuity should exist. 
  4. Also check harness for short to ground and short to power.

OK or NG 

  1. OK: GO TO 4.
  2. NG: Repair open circuit or short to ground or short to power in harness or connectors.