Door Lock/Unlock Switch Check
- CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
With CONSULT-III
Check door lock/unlock switch ("CDL LOCK SW", "CDL UNLOCK SW") in DATA MONITOR mode in CONSULT-III. Refer to "DATA MONITOR ".
- When door lock/unlock switch is turned to LOCK:
CDL LOCK SW : ON
- When door lock/unlock switch is turned to UNLOCK:
CDL UNLOCK SW : ON
Without CONSULT-III
- Remove key from ignition key cylinder.
- Check the signal between BCM connector M18 terminal 22 and ground with oscilloscope when door lock/unlock switch is turned to LOCK or UNLOCK.
- Make sure the signals which are shown in the figure below can be detected during 10 seconds just after the door lock/unlock switch is turned to LOCK or UNLOCK.TERMINALS VOLTAGE CHART
Connector Terminal Voltage (V) (Approx.) ( + ) ( - ) M18 22 Ground
OK or NG
OK: Door lock and unlock switch circuit is OK.
NG: GO TO 2.
- When door lock/unlock switch is turned to LOCK:
- CHECK BCM OUTPUT SIGNAL
Check ("POWER WINDOW DOWN") in ACTIVE TEST mode for "MULTI REMOTE ENT" with CONSULT-III. Refer to "ACTIVE TEST ".
When "ACTIVE TEST" is performed, are the front windows lowered?
Yes or No
Yes: GO TO 3.
No: Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".
- CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch or power window and door lock/unlock switch RH.
- Check continuity between main power window and door lock/unlock switch connector D7 terminal 15 (without automatic back door system) or D8 terminal 17 (with automatic back door system) and ground.
15 - Ground : Continuity should exist.
17 - Ground : Continuity should exist.
- Check continuity between power window and door lock/unlock switch RH connector D105 terminal 11 and ground.
11 - Ground : Continuity should exist.
OK or NG
OK: GO TO 4.
NG: Repair or replace harness.
- CHECK POWER WINDOW SERIAL LINK CIRCUIT
- Disconnect BCM.
- Check continuity between BCM connector M18 terminal 22 and main power window and door lock/unlock switch connector D7 terminal 12 (without automatic back door system) or terminal 14 (with automatic back door system).
22 - 12 : Continuity should exist.
22 - 14 : Continuity should exist.
- Check continuity between BCM connector M18 terminal 22 and power window and door lock/unlock switch RH connector D105 terminal 16.
22 - 16 : Continuity should exist.
OK or NG
OK: Replace main power window and door lock/unlock switch or power window and door lock/unlock switch RH. Refer to "REMOVAL AND INSTALLATION ".
NG: Repair or replace harness.