CONSULT-II Reference Value in Data Monitor Mode
WARNING: This page is about a different car, the 2006 Nissan Pathfinder. However, it is still accessible from the selected car via links, so may be relevant.
Specification data are reference values.
CONSULT II DATA MONITOR MODE REFERENCE VALUE
| MONITOR ITEM | CONDITION | SPECIFICATION | |||
|---|---|---|---|---|---|
| ACCEL SEN 1 |
|
Accelerator pedal: Fully released | 0.65 - 0.87V | ||
| Accelerator pedal: Fully depressed | More than 4.3V | ||||
| ACCEL SEN 2(1) |
|
Accelerator pedal: Fully released | 0.56 - 0.96V | ||
| Accelerator pedal: Fully depressed | More than 4.0V | ||||
| CLSD THL POS |
|
Accelerator pedal: Fully released | ON | ||
| Accelerator pedal: Slightly depressed | OFF | ||||
|
|||||