Door Lock/Unlock Switch Check
WARNING: This page is about a different car, the 2008 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL
With CONSULT-III
Check door lock/unlock switch ("CDL LOCK SW", "CDL UNLOCK SW") in DATA MONITOR mode in CONSULT-III. Refer to "DATA MONITOR "
- When door lock/unlock switch is turned to LOCK:
CDL LOCK SW: ON
- When door lock/unlock switch is turned to UNLOCK:
CDL UNLOCK SW: ON
Without CONSULT-III
- Remove key from ignition key cylinder.
- Check the signal between BCM connector M18 terminal 22 and ground with oscilloscope when door lock/unlock switch is turned to LOCK or UNLOCK.
- Make sure the signals which are shown in Fig 1 can be detected during 10 seconds just after the door lock/unlock switch is turned to LOCK or UNLOCK.
BCM CONNECTOR M18 TERMINAL 22 AND GROUNDConnector Terminals Voltage (V) (Approx.) (+ ) (-) M18 22 Ground Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: Door lock and unlock switch circuit is OK.
NG: GO TO 2.
- When door lock/unlock switch is turned to LOCK:
- CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch or power window and door lock/unlock switch RH.
- Check continuity between main power window and door lock/unlock switch connector D8 terminal 17 and ground.
17 - Ground: Continuity should exist.
- Check continuity between power window and door lock/unlock switch RH connector D105 terminal 11 and ground
11 - Ground: Continuity should exist.
OK or NG
OK: GO TO 4.
NG: Repair or replace harness.
- CHECK POWER WINDOW SERIAL LINK CIRCUIT
- Disconnect BCM.
- Check continuity between BCM connector M18 terminal 22 and main power window and door lock/unlock switch connector D7 terminal 14.
22 - 14: Continuity should exist.
- Check continuity between BCM connector M18 terminal 22 and power window and door lock/unlock switch RH connector D105 terminal 16.
22 - 16: Continuity should exist.
- Check continuity between BCM connector M18 terminal 22 and ground.
22 - Ground: Continuity should not exist.
OK or NG
OK: Replace main power window and door lock/unlock switch or power window and door lock/unlock switch RH.
NG: Repair or replace harness.