Diagnostic Procedure
- CHECK FUEL LEVEL SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 78 and ground.
Refer to Wiring Diagram .
Continuity should exist.
- Also check harness for short to power.
OK or NG
- OK : GO TO 3.
- NG : GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors F59, M71
- Harness for open and short between ECM and ground
- : Replace open circuit or short to power in harness or connectors.
- CHECK FUEL LEVEL SENSOR
Refer to "FUEL LEVEL SENSOR UNIT CHECK ".
OK or NG
- OK : GO TO 4.
- NG : Replace fuel level sensor unit.
- CHECK INTERMITTENT INCIDENT
Refer to "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT ".
- : INSPECTION END