6. Check Refrigerant Pressure Sensor Input Signal Circuit For Open And Short
- Check harness continuity between ECM terminal 70 and refrigerant pressure sensor terminal 2. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8. CHECK INTERMITTENT INCIDENT .
NG >> GO TO 7. DETECT MALFUNCTIONING PART .