9. Check Stop Lamp Switch Input Signal Circuit For Open And Short
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 101 and stop lamp switch terminal 2. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
OK >>GO TO 10. CHECK STOP LAMP SWITCH .
NG >>Repair open circuit or short to ground or short to power in harness or connectors.